GA500 Plus
Rugged, hand-held instrument that identifies and measures percent
purity of R134a, R12, R22
and Hydrocarbons with 98% accuracy.
Features
- One Button for Quick, Easy Operation
- Rugged, hand-held tool
- Identifies and measures % purity
of R134a,
R12
and R22
and hydrocarbons with 98% accuracy
- Audible and visual alarms for
flammable hydrocarbons
- Indicates presence of blends
and contaminated refrigerants
- Printer port for record retention
- Features one-button testing
with a total test cycle time of <60 seconds
- Automatic Altitude compensation
- 12 VDC, or optional Universal
AC power adapter
Specifications
- Measures: R12, R134a,
R22, and Hydrocarbons
- Size: 5.4" x 8" x 2.5 "
- Power: 12V Battery or AC Adapter
- Operating Temperature: 50 to 120 °F
- Purity Accuracy: +1% from 90 to 100% by weight
- Resolution: +0.1% by weight over the operating temperature
range
- Measurement Time: <60 seconds
- Data Display:
- LCD simultaneously shows % purity of R134a,
R12, R22, and
hydrocarbons and % of air by weight
- R-12 Green LED lights if purity is 98%
- R-134a Green LED lights if purity is 98% or greater
- Contaminated Yellow LED lights if:
- Purity of R-12 or R-134a is <98%
- System contains >2% R-22
- System contains >2% SNAP approved blends or refrigerants
other than R12, R134a,
R22, and hydrocarbons
- Flammable Gas Red LED flashes if system contains >2% of hydrocarbons
(in addition, horn alarms)
|